Coverage Area |
Water Removal Capacity |
Energy Factor (L/kWh) |
Pints/ kWh |
Operating Temperature Range |
CFM |
Bucket Capacity |
Bucket Position |
Drain Hose |
Auto Restart |
|
|
Up to 1700 sq ft |
80 pints per day set @ 80°F, 60% |
- |
- |
41 to 90°F |
236 |
- |
- |
- |
- |
|
|
Up to 800 sq ft |
52 pints per day set @ 80°F, 60% RH, 12 gallons at saturation |
- |
- |
33°F - 95°F |
282 |
- |
- |
- |
- |
|
|
Up to 400 sq ft |
17 pts pints per day set @ 80°F, 60% RH |
- |
- |
33°F - 95°F |
170 cfm |
- |
- |
- |
- |
|
|
Up to 500 sq feet |
17 pints per day set @ 80°F, 60%RH, 6 gallons at saturation |
- |
- |
33 to 95°F |
170 cfm |
- |
- |
- |
- |
|
|
Up to 800 sq ft |
52 pints per day up to set @ 90°F 90% humidity, 12 gallons in extreme conditions |
- |
- |
33°F - 95°F |
282 |
- |
- |
- |
- |
|
|
- |
- |
- |
- |
- |
1600, 2000, 2500 cfm |
- |
- |
- |
- |
|
|
3,000 sq. ft. |
Up to 97 pints per day set @ 80°, 60% RH, 20 gallons at saturation |
- |
- |
33°F - 95°F |
700 cfm |
- |
- |
- |
- |
|
|
Up to 1500 sq ft |
Up to 56 pints per day set @ 80°F, 60% RH |
- |
- |
33°F - 95°F |
360 cfm |
- |
- |
Yes - hose is 3/8"W x 25'L |
- |
|
|
Up to 1800 sq ft |
105 pints per day set @ 80°F, 60%, 28 gallons at saturation |
- |
- |
33 to 105°F |
437(low) - 538(max) |
- |
- |
- |
- |
|
|
Up to 1800 sq. ft. |
105 pints per day set @ 80°F, 60%, 28+ gallons at saturation |
- |
- |
33° - 105°F |
Low: 437 CFM High: 538 CFM |
- |
- |
- |
- |
|
|
Up to 3000 sq ft |
Up to 97 pints per day set @ 80°, 60% RH, 20 gallons at saturation |
- |
- |
33°F - 105°F |
700 cfm |
- |
- |
- |
- |
|
|
- |
138 pints per day set @ 80°F, 60%RH |
- |
- |
33°F – 95°F |
Low: 585 High: 664 |
- |
- |
- |
- |
|
|
Up to 1,500 sq ft |
Up to 56 pints per day set @ 80°F, 60%, 15 gallons at saturation |
- |
- |
33°F - 95°F |
360 |
- |
- |
- |
- |
|
|
Up to 1500 sq ft |
56 pints per day set @ 80F, 60%RH, 15 gallons at saturation |
- |
- |
33°F - 105°F |
360 cfm |
- |
- |
- |
- |
|
|
Up to 1700 sq ft (12000-13000 cu. ft.) |
87 pints per day set @ 80°F, 60%RH, 20 gallons at saturation |
- |
- |
41°F - 95°F |
300 cfm (max) |
- |
- |
- |
- |
|
|
Up to 1800 sq ft |
67 pints per day set @ 80°F, 60%, 27 gallons at saturation |
- |
- |
33 - 105°F |
650 cfm |
- |
- |
- |
- |
|
|
1500 sq. ft. |
56 pints per day set @ 80°F, 60%RH |
- |
- |
33°F – 95°F |
360 |
- |
- |
- |
- |
|
|
Up to 375 sq. ft. |
17 pints per day set @ 80°F, 60% |
- |
- |
50° - 80°F |
150 CFM (250 M3/HR) |
- |
- |
- |
- |
|
|
Up to 1000 sq ft |
56 pints per day set @ 80°F, 60%, 15 gallons at suturation |
- |
- |
33°F - 95°F |
360 |
- |
- |
25' hose |
- |
|
|
Up to 10,000 sq ft |
Up to 285 pints per day set @ 80°F, 60% RH, 50 gallons at saturation |
- |
- |
33°F - 95°F |
1750 |
- |
- |
- |
- |
|
|
Not rated. For small areas. |
28.6 pints per day set @ 90F |
- |
- |
0 to 110 degrees |
2 blowers: Process air 55 CFM, regeneration air 55 CFM |
- |
- |
- |
- |
|
|
Not rated. Will vary due to conditions. |
192 pints per day set @ 70F, 80%RH |
- |
- |
0 to 110 degrees |
2 blowers: Process air 150 CFM, regeneration air 70 CFM |
- |
- |
- |
- |
|
|
- |
106 pints per day set @ 80°F, 60% RH |
- |
6.8 |
33°F – 110°F |
255 CFM without external ducting 170 CFM at .15 IWG external static |
N/A – no buckets required |
- |
- |
- |
|
|
- |
183 pints per day set @ 80°F, 60% RH |
- |
- |
33°F – 110°F |
540 CFM without external ducting 510 CFM @ .15 IWG external static |
N/A – no buckets required |
- |
- |
- |
|
|
- |
185 pints per day set @ 80°F, 60% RH |
- |
- |
33°F – 110°F |
540 CFM without external ducting 510 CFM @ .15 IWG external static |
N/A – no buckets required |
- |
- |
- |
|
|
- |
200 pints per day set @ set at 80°F, 60% RH |
- |
- |
33°F – 95°F |
Low: 585 High: 664 |
- |
- |
- |
- |
|
|
- |
110 pints per day set @ at 80°F, 60% RH |
- |
- |
33° - 95°F |
Low: 261 High: 491 |
- |
- |
- |
- |
|
|
Up to 1500 sq. ft. |
56 pints per day set @ 80 F, 65%,15 gallons at saturation |
- |
- |
33° - 105°F |
360 CFM |
- |
- |
- |
- |
|
|
Up to 2500 sq. ft. |
67 pints per day set @ 80 F, 65% RH, 27 gallons at saturation |
- |
- |
33° - 105°F |
650 CFM |
- |
- |
- |
- |
|
|
Not rated. For small areas. |
over 2 pints per hour at 90F |
- |
- |
0 to 110 degrees |
2 blowers: Process air 100 CFM, regeneration air 100 CFM |
- |
- |
- |
- |